Intelligent Dimming PLC Control Cabinet Scene Mode Timed Control
Product Describe:
1. Large commercial buildings
Public areas (corridors, atriums) and shop windows in malls and shopping centers, where brightness can be automatically adjusted based on foot traffic and time to balance lighting effects and energy savings.
2. Municipal and public facilities
Urban roads, tunnels, parks, and squares, where dimming is automated based on sunrise/sunset times and traffic/pedestrian density to reduce municipal energy consumption; quick switching to high-brightness mode in emergencies.
3. Cultural and sports venues
Stadiums, theaters, and convention centers, where brightness and color temperature in different areas are precisely controlled to match event needs (competitions, performances, exhibitions).
4. Medical and educational institutions
Hospital wards and school classrooms, where dimming creates a comfortable environment (e.g., low-brightness lighting in wards at night) while meeting specific needs (e.g., high-precision lighting control in operating rooms).
Design:
• Conventional Sizes
Small-sized: Common sizes include 1200(H) × 600(W) × 400(D)mm, etc. They are suitable for small-scale equipment control or places with limited space, such as lighting control of small production lines.
• Medium-sized: These include 2200(H) × 800(W) × 600(D)mm, 2200(H) × 800(W) × 800(D)mm, etc. They can meet the lighting control needs of small and medium-sized enterprise production lines and some automation systems, and can accommodate more modules and components.
• Large-sized: For example, 2200(H) × 1600(W) × 800(D)mm. They are suitable for large-scale places such as large production lines and chemical plants, and can install a large number of components to meet complex intelligent dimming control requirements.
• Custom Sizes: They can be customized according to factors such as actual installation space, the number of control devices, and the complexity of control circuits. For instance, if the installation space is narrow, a thinner or narrower cabinet can be customized; if a large number of devices and circuits need to be controlled, the width, depth, or height of the cabinet can be increased to accommodate more modules and cables, ensuring the normal operation of the equipment and facilitating maintenance.
IP Grade:
IP54 / IP55 / IP65 / IP66
Suggestion:
1. Space Adaptation
Match dimensions to the installation site, reserve ≥600mm maintenance access, and avoid obstacles.
2. Control Requirement Matching
Design internal layout based on the number of circuits and module types; increase depth for complex scenarios (100+ circuits).
3. Environmental Adaptation
Humid/outdoor conditions: Choose IP54+ protection, 304 stainless steel, and add rainproof seals.
High-temperature environments: Install cooling fans or thermostat systems.
4. Design Optimization
Adopt a modular structure (reserve 20-30% space for future upgrades), separate high and low voltage zones, and equip cabinet doors with observation windows and safety locks.