Guangzhou Hengmeida Automation Technology Co., Ltd

Rapid-response, exceptional results - customized solutions for your business.

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Direct Digital Control Cabinet /

Smart Building Control Cabinet Reliable Electrical Enclosure for HVAC, Lighting & Automation Systems

Contact Now
Guangzhou Hengmeida Automation Technology Co., Ltd
Visit Website
City:guangzhou
Country/Region:china
Contact Person:MrsLueng
Contact Now

Smart Building Control Cabinet Reliable Electrical Enclosure for HVAC, Lighting & Automation Systems

Ask Latest Price
Video Channel
Model Number :JL1561541566
Certification :CE
Place of Origin :China
MOQ :5
Price :USD28-68889
Payment Terms :T/T,Western Union
Delivery Time :15 Days
Packaging Details :Wooden case/ Carton
Usage :Electrical equipment storage/ Industrial/ Building Control
Weight :Varies based on size
Ventilation :Yes
Mounting Type :Wall-mounted,Floor Standing,Pole Mount
Fireproof :No
Waterproof :Yes
Certifications :CE
Shape :Rectangular
Number Of Shelves :Adjustable
Number Of Doors :Single/Double
Size :Customizable
Material :Metal
Lock Type :Key lock
Color :Grey/Others
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
Smart Building Control Cabinet | Reliable Electrical Enclosure for HVAC, Lighting & Automation Systems
Product Attributes
Attribute Value
Usage Electrical equipment storage/ Industrial/ Building Control
Weight Varies based on size
Ventilation Yes
Mounting Type Wall-mounted, Floor Standing, Pole Mount
Fireproof No/Yes
Waterproof Yes/No
Certifications CE
Shape Rectangular
Number Of Shelves Adjustable
Number Of Doors Single/Double
Size Customizable
Material Metal
Lock Type Key lock
Color Grey/Others
Product Description
1.HVAC Systems
Regulate heating, cooling, ventilation, and air quality—e.g., adjusting home AC by room temperature; optimizing zone-specific airflow in offices/malls; maintaining precise temp/humidity for industrial workshops.
2. Lighting Control
Enable smart lighting—auto-on/off/dimming in lobbies/parking garages via motion/light sensors; scene-based lighting (e.g., "opening/closing modes" for hotels/stores); app/timer control in smart homes.
3. Power Management
Monitor/distribute power—track floor-level energy use in high-rises; ensure stable UPS power for data center servers; adjust industrial production line power and trigger overload alarms.
4. Security & Access Control
Integrate with intercoms, access readers (RFID/facial recognition), and cameras—authorize entry for residents/employees; alert on unauthorized access in communities/offices.
Design Specifications
Type Common Dimensions (H × W × D, mm)
Wall-mounted

500 × 400 × 150
600 × 500 × 200

800 × 600 × 200

1000 × 800 × 200

1200 × 1000 × 200

Floor-standing 1400 × 600 × 500
1800 × 800 × 600
2000 × 1000 × 600
2200 × 800 × 800
1800 × 1200 × 400
2000 × 1600 × 500
Special Sizes 508 × 508 × 254 (20in×20in×10in)
762 × 762 × 254 (30in×30in×10in)
Custom Custom on requirement
IP Rating Specifications
IP Rating Protection Capability Application Scenarios Special Requirements
IP20 Protects against ≥12.5mm solids/No water protection Dry indoor environments (electrical rooms, server rooms) Standard steel plate, no special sealing required
IP54 Dustproof + Splash-proof Industrial workshops (light dust/humidity) Door gaps require sealing strips
IP55 Dustproof + Low-pressure water jet protection Outdoor uncovered areas Full weld seams required, surface powder coating
IP65 Complete dustproof + High-pressure water jet protection Harsh environments (ports, mines, etc.) Double sealing structure + Drainage design
IP66 Complete dustproof + Powerful water jet protection Ship decks, petrochemical plants 304 stainless steel hinges + Pressure relief valve
Configuration Suggestions
1. Function adaptation: Determine the input/output modules, sensor types, and control logic that need to be integrated based on the control object (such as only air conditioning/including lighting+security, etc.).
2. Scale matching: Select controller specifications based on project volume (small building/large complex), and clarify whether redundant configuration or expansion modules are required.
3. Protocol compatibility: Confirm the protocols (such as BACnet IP, Modbus TCP) of the building systems (such as BMS, security systems) that need to be connected to ensure data interoperability.
4. Environmental adaptation: Determine the enclosure protection level (such as IP54/IP65) and temperature and moisture resistance performance based on the installation scenario (indoor computer room/outdoor pipe gallery).
5. Operational requirements: Determine whether to configure HMI human-machine interface and the complexity of interface operation (basic parameter settings/advanced data analysis).
6. Safety standards: Follow the electrical safety regulations (such as national/European standards) of the project location, and configure appropriate overload protection, lightning protection, and encryption modules.